The key specification of KSTAR UPS UA60 – 600VA/360W are as follows:
| Type | Line Interactive UPS |
| Model | UA60 |
| Capacity (VA/Watts) | 600VA/360W |
| Safety / Protection | Overload And Overcharge Protection |
| Indicators | AC Mode, Battery Mode, Load Level, Battery Leve |
| Input/Output | UPS Input/Output : 1P+N+E / 1P+N+E (230V 50Hz) Universal Power Outlet, Output Sockets : 02 Nos |
| Other Features Part 1 | Excellent Microprocessor Control Guarantees High Reliability. (Internal Self-Diagnostic Technology), Boost And Buck AVR For Voltage Stabilization. (Wide Input Range With Two Boost And One Buck Control) |
| Other Features Part 2 | Auto Restart While Ac Is Recovering. | Cold Start Function. | Off-Mode Charging. | Fast Intelligent Battery Recharge Function. | Generator Compatible. |
| Standards | Safety: IEC/EN62040-1;IEC/EN60950-1 | EMC: IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4;IEC61000-4-5;IEC61000-4-6;IEC61000-4-8 |
| Dimensions | 101×298×142 W x D x H (mm) |
| Weight | 4.3 kg |
| Colors | Black |
| Other Information |
|
Input
| Nominal Input Voltage | 220/230/240 Vac |
| Operating Voltage Range | 140~300 Vac |
| Operating Frequency Range | 50/60 Hz (1±10%) (Auto Sensing) |
Output
| Output Voltage Range (Batt. Mode) | Simulated Sinewave At Nominal Voltage ±10% |
| Frequency Range (Batt. Mode) | 50 Hz Or 60 Hz ± 1 Hz |
| Transfer Time | Typical 2-6 ms, 10ms Max. |
| Waveform (Batt. Mode) | Simulated Sinewave |
Battery
| Voltage | 12Vdc |
| Battery Type / Number | 12V/7Ah x 1 |
| Typical Recharge Time | 4-6 Hours ( To 90% Capacity) |
Alarm
| Battery Mode | Sounding Every 10 Seconds |
| Battery Low | Sounding Every Second |
| Overload | Sounding Every 0.5 Second |
| Battery Replacement Alarm | Sounding Every 2 Seconds |
| Fault | Continuously Sounding |
Environment
| Operating Temperature | 0 – 40°C |
| Humidity Range | 0-95 % (Non-Condensing) |
| Noise Level | <40db (1 Meter From Surface) |
Features
AVR Boost and Buck
Automatically corrects either under-voltage or over-voltage condition without unnecessary battery drain and extend the life of the battery.
Cold Start Function
Aids users to turn on the UPS without connecting the Utility.
Built-in Self-diagnostic Function
May execute automatically upon power-on or software-control.
Compatible with Generator Set
Micropower series supports wide range input voltage to fit with various generator sets.
Fastest Charging Capacity
With built-in powerful charger, the UPS can be fully charged back to 90% in 4-6 hours.
Auto Charging at Off Mode
The battery may be charged continuously even though it is at OFF mode.
Auto-restart Function
The UPS will be automatically re-started when Utility recovers.